Product Information and Details
Large meter display (with back light) of sound loudness, allowing the user to pinpoint the exact leak location.
Light weight amplifier, weighing only 31 ounces, with a padded carrying case and a strap.
Six selectable filters, split into three "low side" filters (100Hz, 200Hz, or 400Hz) and three "high side" filters (600Hz, 800Hz, or 1200Hz).
"Limiter" switch which cuts off all loud noises greater than 110dB. If you drop the sensor, you won't hurt your hearing.
"Filter-Thru" switch, which turns OFF all of the amp’s filters, allowing the user to hear all sounds from 50Hz to 15,000Hz.
High-sensitivity ground microphone and low "electronic noise" amplifier combine to offer the very best quality sound for leak detection.
Three accessories for attachment to the sensor:
Ground plate for pinpointing on streets/slabs
Magnet base for surveying at hydrants/valves
Contact rod for surveying at meters/fittings
Items in Photo Shown:
1. Amplifier with Meter Display and Filter Controls
2. Ground Microphone and Handswitch
3. Aviation-Grade Stereo Headphones
4. Heavy-Duty ABS Plastic Carrying Case
5. Magnet Base
6. 3-Section Contact Rod
7. Nut Driver (to remove base)
8. Instruction Manual (not shown)
Amplifier
Input Impedance: 50k ohms
Output Impedance: 15 ohms
Amplification: 62 dB +/- 3dB
Frequency Range: 1) 100Hz to 1200Hz (13 dB) with Filter-Thru OFF 2) 15Hz to 30,000Hz (13 dB) with Filter-Thru ON
Power: 6 AA dry cell batteries
Power Consumption: 1) 70 mA or less with backlight ON 2) 35 mA or less with backlight OFF
Battery Life: 1) 14 hours with backlight ON 2) 28 hours with backlight OFF
Weight: 31 ounces (885 g)
Size: 6.7" x 2.8" x 4.1" (170mm x 70mm x 103mm)
ABS Carrying Case
Weight (full): 15 lb. (6.81 Kg)
Size: 18.5" x 14.6" x 7.5" (470mm x 371mm x 190mm)
Manufacturers 5 Year Warranty.